6.3.3

Technical specifications

Core statement
Order number
Product
Power supply, type
Input
Input
Rated voltage value Vin rated
Voltage range AC
Wide-range input
Mains buffering at Iout rated, min.
Rated line frequency 1
Rated line frequency 2
Rated line range
Input current
at rated input voltage 400 V
at rated input voltage 500 V
Switch-on current limiting (+25 °C), max.
I²t, max.
Built-in incoming fuse
Protection in the mains power input (IEC 898)
Output
Output
Rated voltage Vout DC
Total tolerance, static ±
Static mains compensation, approx.
Static load balancing, approx.
Residual ripple peak-peak, max.
Spikes peak-peak, max. (bandwidth: 20 MHz)
Adjustment range
Product function Output voltage adjustable
Output voltage setting
Status display
Signaling
On/off behavior
Startup delay, max.
Voltage increase time of the output voltage
maximum
Rated current value Iout rated
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
6EP3446-8SB10-0AY0
SITOP PSU8200
36 V/13 A
3-phase AC
400 ... 500 V
320 ... 575 V
Yes
15 ms; at Vin = 400 V
50 Hz
60 Hz
47 ... 63 Hz
1.2 A
1 A
16 A
0.8 A²·s
none
Required: 3-pole connected miniature circuit
breaker 6 ... 16 A characteristic C or circuit
breaker 3RV2011-1DA10 (setting 3 A) or
3RV2711-1DD10 (UL 489)
Controlled, isolated DC voltage
36 V
3 %
0.1 %
0.2 %
100 mV
200 mV
36 ... 42 V
Yes
via potentiometer; max. 480 W
Green LED for 36 V OK
Relay contact (NO contact, rating 60 V DC/ 0.3 A)
for 36 V OK
No overshoot of Vout (soft start)
2.5 s
500 ms
13 A
6.3 SITOP PSU8200 13A/36V 3-phase
Power supply
233