A.1.2.9

TZW3, TZW4, TZW5 - Technology status words 3, 4, 5

The values monitored in the technology status words TZW3, TZW4 and TZW5 can be set via
the parameters p4700, p4701 and p4702.
Table A- 34
Parameter Value range
p4700
p4701
p4702
The default values of the parameters p4700, p4701, p4702 correspond to the settings for
TZW3, TZW4, TZW5 in FW versions < V1.09.
Table A- 35
Value
0
1
2
3
4
5
6
7
8
9
Table A- 36
15 - 5
Reserved
Table A- 37
Group
D-IN
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Value setting for TZW3, TZW4, TZW4
Default
value
0 ... 9
0
0 ... 9
1
0 ... 9
2
Value selection for TZW3, TZW4, TZW4
Description
D-IN
D-OUT
Button
Door position in mm
Door setpoint speed in mm/s
Door actual speed in mm/s
Motor current in mA
Motor current limitation in mA
Voltage of the motor output stage in V
Remaining power capacity of the braking resistor in J
TZW data structure for value "D-IN"
Bits "D-IN"
Bit
Meaning
0
Input 0
1
Input 1
2
Input 2
3
Input 3
4
Input 4
Reserved
5 - 15
A.1 Structure of user data/process data
Description
Value selection for TZW3 (see following tables)
Value selection for TZW4 (see following tables)
Value selection for TZW5 (see following tables)
Format
For data structure, see table A-35
For data structure, see table A-37
For data structure, see table A-39
16-bit unsigned integer
16-bit unsigned integer
16-bit unsigned integer
16-bit signed integer
16-bit signed integer
16-bit unsigned integer
16-bit signed integer
TZW3, TZW4, TZW5
Comment
X6, INPUT 1
X6, INPUT 2
X6, INPUT 3
X6, INPUT 4
X5, INPUT 0
Appendices
4
3
2
1
0
D-IN
297