Installing the Control System

2.1

Installing and removing the SINUMERIK 802S

Warning
!
Before performing any installation work, always first make sure that the system is disconnec-
ted from the mains!
The modules contain electrostatically sensitive devices.
It must be ensured that persons without ESD protection never touch printed circuit boards or
components when handling operator and machine control panels.
Approach
Prior to installation, the machine control panel can be provided with a spindle override switch
and an emergency stop button. If these are not required, the openings must be covered with
the supplied self–adhesive covers.
1. Mount the spindle override switch.
2. Install the operator panel and the machine control panel.
3. Connect the panel using ribbon cable.
4. Install the DIN rail.
5. Connect the ENC and DI/O components.
Note
If you want to connect several DI/O16 components, it may be necessary to remove the right–
hand connector from the housing.
6. Slide the components onto the DIN rail, tilt it down and screw it tight.
Removing the control system
The control components are removed as described above in the reverse order.