Siemens SIDOOR ATD401W System Manual page 84

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

SIDOOR functions
3.3 Extended functions
Changed basic parameters only take effect at standstill.
If the write protection is set via parameters p90, the basic parameters cannot be changed
through the menu system.
During initial commissioning, after resetting the parameter memory via p91, or after changing
the motor type, the basic parameters are reset to their default values. Subsequently, all basic
parameters must be confirmed by writing at least once (even if the value displayed
corresponds to the desired value).
After setting the basic parameters, the limits for the drive curve parameters (deceleration and
acceleration ramps, maximum speeds and forces) are calculated according to the basic
parameters (door weight and output ratio). If the previously set drive curve parameters are
outside the calculated limits, the drive curve parameters are corrected so that they are within
the parameter limits.
After changing the basic parameters (in particular the door weight and output ratio), it is
recommended to check and adjust the travel curve parameters or to load the default
parameters.
Control of the basic parameter editor via PROFIdrive
The status of the basic parameters editor can be determined and changed via parameter
p2111:
Read p2111:
0 -> Basic parameter editor is not active. The basic parameters are read-only.
1 -> Basic parameter editor is running. The basic parameters can be changed.
Write p2111:
0 -> Cancel basic parameter editor. Changed basic parameters are discarded.
1 -> Start basic parameter editor. Basic parameters can be changed.
2 -> Close basic parameter editor and save the parameters.
If not all basic parameters were written with an initial commissioning or after resetting the
parameter memory via p91, the write operation is terminated with an error message (6 wrong
value). Changes to the parameter settings are discarded.
Control of the basic parameter editor via menu system
With the menu command "General setup -> Basic parameters", you can open basic
parameters editor in the menu (see also section "Navigation Structure in SIDOOR Service
Tool (Page 246)").
If the menu command "Change Basic Parameters" is not selected with CR, the basic
parameters are only displayed.
If the menu command "Change Basic Parameters" was selected with CR, it changes to
"Save Basic Parameters" and the basic parameters can be changed.
After all basic parameters have been changed or confirmed with CR, you can select "Save
basic parameters". The basic parameters are saved and the menu command returns to
"Change Basic Parameters".
If not all basic parameters were changed or confirmed with CR with an initial commissioning
or after resetting the parameter memory via p91, an error message is displayed. Changes to
the parameter settings are discarded.
84
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sidoor atd420wSidoor atd410wSidoor atd430w

Table of Contents