A.1.2.8

TZW2 - Technology status word 2

Table A- 29
Reserved
IMPDRVIncr and IMPDRVVelo signals
The signals IMPDRVIncr and IMPDRVVelo are in the low byte of TZW2 (bits 0 to 2, and
bits 3 to 5). Both have a numeric structure.
Table A- 30
IMPDRVIncr
signal value
0
1
2
8
Table A- 31
IMPDRVVelo
signal value
0
1
2
8
Note
The IMPDRVIncr and IMPDRVVelo signals as well as the lead time are reset on the
transition of the sequential control system to the "S4: Z_operation" (see Figure 4-4
Sequential control state graph (Page 149)) state. This decouples the ImpDrv signals from the
service mode (local operation) and operating mode.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Technology status word 2 (TZW2)
15 ... 11
10 ... 9
ASStp
IMPDRVIncr signal
Name
ImpDrvInaktiv
ImpDrvOpen
ImpDrvClose
Reserved
IMPDRVVelo signal
Name
ImpDrvInaktiv
ImpDrvOpen
ImpDrvClose
Reserved
A.1 Structure of user data/process data
TZW2
8
7 ... 6
ASDRV
Reserved
Description
No ImpDrv detected or inactive
tion)
ImpDrv is detected in the opening direction
dependent detection)
ImpDrv is detected in the closing direction
dependent detection)
...
Description
No ImpDrv detected or inactive
ImpDrv is detected in the opening direction
dependent detection)
ImpDrv is detected in the closing direction
detection)
...
Appendices
5 ... 3
2 ... 0
IMPDRVVelo
IMPDRVIncr
(distance-dependent detec-
(distance-
(distance-
(speed-dependent detection)
(speed-
(speed-dependent
295