6. The display on the controller is as follows:
– The 7-segment display (H401) shows "H.". The decimal point in the 7-segment display
– The LCD display (H1) shows "'H': learn run activated".
7. The door can now be opened with the OPEN button (S402).
– The 7-segment display (H401) shows "o" while the door is opening.
8. Switch off the controller by pulling out the power plug or the connector X3.
9.5

Connecting digital inputs

Connecting digital inputs
Connecting digital input signals
1. Insert the terminal connectors for the digital control inputs in X6, X5 and X4. See section
Digital input signals (Page 108) for more on this.
Note
Risk of injury through moving mechanical parts.
The controller will be operative after the next switch-on. If a control signal is present, the
door will move in the set direction.
2. Select the FBLOCK configuration according to the wiring of the input signals via the
service menu. See section Digital input signals (Page 108) for more on this.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
(H401) flashes during the save process.
The 7-segment display (H401) shows "u" when saving has finished. If a light
barrier/pressure-sensitive edge (SIDOOR ATD4xxW) is used, the 7-segment display
(H401) shows "0." because X6 is not yet connected.
For the M4, MDG400. MDG400NMS and M5 motors, the determined mass to be
moved is shown on the LCD for the initial commissioning or motor adaptation.
Connecting and commissioning
9.5 Connecting digital inputs
267