Power supply
6.2 SIDOOR Transformer
6.2.2
Installation
Requirements
The installation site must fulfill the following requirements:
● Minimum clearance to surrounding parts: 1 cm
● Even mounting surface
● Maximum distance from the power supply due to cable length:
– Connecting cable input line (network ⇔ transformer): 200 cm
– Connecting cable output line (transformer ⇔ controller): 150 cm
Risk of fire
The temperature of the housing of the transformer can rise to over 105 °C in the event of a
fault in the controller or a short circuit in the output line of the transformer.
As a result, you should take the following safety measures:
• Only mount the transformer on surfaces with no risk of ignition, and which cannot be
• Inform the service personnel about the risk of fire.
Material damage
The transformer power supply cable cannot be replaced.
If the cable is damaged, the device must be scrapped.