Maintenance - Siemens SIDOOR ATD401W System Manual

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

Alarms
Remedying alarms
Display
4
5
P / _
y
1)
SIDOOR ATD410W/ATD420W/ATD430W
1)
10.3

Maintenance

The SIDOOR system should be included in the maintenance schedule for the door system
as a whole, and inspected in the course of the maintenance cycles stated in the schedule.
Note
Recommended maintenance cycles provided in the table below may vary according to the
ambient conditions and the stress on the system.
Object
DC geared motor
SIDOOR control unit
Visual inspection of the control unit, the fastening of the
motor mount, the pulley and the mounting brackets for dirt,
damage and proper installation. In addition, an inspection of
the door function is recommended for running or grinding
noises.
The belt tension should be checked
With mechanical changes of the system, for example, due to maintenance or wear (friction, dirt, engine replacement, belt
replacement or modification of the general door mechanism), an inspection is recommended for the commissioning pa-
rameters relating to the safety-related settings for forces and energies/velocities.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB
Remedy
If possible, the system's drive cycle time should be reduced.
The new motor type must undergo a learn run. See Section Learn run (Page 29).
It is imperative that a new learn run be performed during ongoing operation.
Communication with the master system is interrupted. The alarm is cleared as soon as
communication is restored.
Recommended maintenance interval
Maintenance-free
Maintenance-free
1 year
1 year
Diagnostic and maintenance
10.3 Maintenance
275

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sidoor atd420wSidoor atd410wSidoor atd430w

Table of Contents