4.9 Operation and configuration of the control unit
Other parameters
Table 4- 33
Other parameters
Parameter ID
Adjustment range
Sensor Module
p4600
0 ≙ inactive
1 ≙ OSSD
2 ≙ DCOPS
3 ≙ SR
p4601
20 ... 5000
p4610
10 ... 30000
0 ≙ "AND0" discrepancy
analysis deactivated
p4611
10 ... 30000
0 ≙ discrepancy analysis
"AND2" deactivated
Faults and alarms
r2100
r2102
0 ≙ special motor
1 ≙ M2
2 ≙ M3 / MDG180
3 ≙ M4 / MDG400
4 ≙ M5
255 ≙ unknown motor
Display and operation
p90
0 ≙ deactivated
1 ≙ activated
176
Factory
Unit
setting
0
30
ms
400
ms
400
ms
0
Description
Local sensor type
Discrepancy time in the function test of the OSSD
system
Discrepancy analysis time of the input monitoring
block FBLOCK "AND0"
Discrepancy analysis time of the input monitoring
block FBLOCK "AND2"
Status code
ASCII code of the 7-segment display (see section
Operating state display (Page 273))
Connected motor
Write protection
Activates (1) or deactivates (0) write protection for
all travel curve parameters in the service menu.
As of V1.09: When write protection is activated via
parameter p90, the FBLOCK configuration, the
force for the learn run and the configuration of digi-
tal input 1 can no longer be changed via the operat-
ing menu.
As of V1.10: When write protection is activated, the
basic parameter cannot be changed via the operat-
ing menu.
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB