Technical Specifications - Siemens SIDOOR ATD401W System Manual

Atd4xxw series, door control systems for industrial applications
Hide thumbs Also See for SIDOOR ATD401W:
Table of Contents

Advertisement

Power supply
6.2 SIDOOR Transformer
6.2.4

Technical specifications

Order number
General technical data:
product brand name
Product designation
Design of the product
Product component Line filter
Electical data:
Supply voltage at AC
Supply voltage frequency at AC
Relative symmetrical tolerance of the supply voltage
Operating current of fuse protection at input when in-
stalling
Consumed current
maximum
Output voltage at DC Rated value Note
Output voltage with pulsating direct voltage RMS value
at full load
at 20 mA
Output current
maximum rated value
Connections:
Type of electrical connection
at input
at output
Wire length
line-side
Output side
Ambient conditions:
Ambient temperature
during operation
during operation Note
during storage
during transport
Installation altitude at height above sea level maximum
Protection class IP
228
6FB1112-0AT20-2TR0
SIDOOR
Power transformer
Transformer
Yes
V
230
Hz
50 ... 60
%
15
6 ... 10
A
2.2
unsmoothed
V
17.3
V
23
A
15.9
SCHUKO connector DIN 49.441,
CEE7/VII
WAGO 721-103/026
m
2
m
1.5
°C
-20 ... +55
No direct exposure to the sun
°C
-20 ... +70
°C
-40 ... +70
m
2 000
IP54
ATD4xxW Door Controller for Industrial Applications
System Manual, 01/2017, A5E38080677-AB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sidoor atd420wSidoor atd410wSidoor atd430w

Table of Contents