In the speed-position switching control (ABS mode) ([Da.2] Control method = Forward run speed-position, Reverse run
speed-position), pulses are output continuously at the speed set in [Da.8] Command speed in the axis direction set to the
positioning data. When Speed-position switching signal is input, the position control to the address set in [Da.6] Positioning
address/movement amount is performed.
The speed-position switching control (ABS mode) has two control types including Forward run speed-position performed in
the forward run direction and Reverse run speed-position performed in the reverse run direction.
The speed-position switching control (ABS mode) is enabled only when 2: degree is set to [Pr.1] Unit setting.
: Setting possible, : Setting not possible (if the item is set, Speed-position function selection error (Error code: 1AAEH)
occurs when PLC READY signal [Y0] is turned on.)
Speed-position function selection
INC mode
ABS mode
The speed-position switching control (ABS mode) can be set to [Pr.150] Speed-position function selection in the detailed
parameter 1.
Setting item
[Pr.150]
Speed-position
function selection
If a value other than 0 and 2 is set, the control is performed in the INC mode with the setting value regarded as 0.
For details on the settings, refer to the following.
Page 399 [Pr.150] Speed-position function selection
Switching from the speed control to position control
• To switch the speed control to the position control, set Speed-position switching signal as External command signal.
• Select a method to switch from the speed control to position control setting the value of [Cd.45] Speed-position switching
device selection.
Setting item
[Cd.45]
Speed-position
switching device
selection
• To switch the speed control to the position control, [Cd.24] Speed-position switching enable flag must be turned on and
positioning data must be set. (When [Cd.24] Speed-position switching enable flag is turned on after Speed-position
switching signal is turned on, the speed control is not switched to the position control. The speed control is switched to the
position control when Speed-position switching signal is turned on again. If [Cd.24] Speed-position switching enable flag
and External command signal are turned on at the start of the control, only the position control is performed.)
Setting item
[Cd.24]
Speed-position
switching enable flag
3 MAJOR POSITIONING CONTROL
132
3.2 Positioning Data Setting
mm
Setting
Setting detail
value
2
Speed-position switching control (ABS mode)
Setting
Setting detail
value
0, 1, 2
Select the device used for the speed to position
switching.
• 0: Use External command signal
• 1: Use Near-point dog signal
• 2: Use [Cd.46] Speed-position switching
command
Setting
Setting detail
value
0, 1
Set whether to enable or disable Speed-position
switching signal.
• 0: Speed control is not switched to position
control even when Speed-position switching
signal is turned on.
• 1: Speed control is switched to position control
when Speed-position switching signal is turned
on.
inch
degree
Buffer memory address
Axis 1
34
Buffer memory address
Axis 1
1566
Buffer memory address
Axis 1
1528
pulse
Axis 2
Axis 3
Axis 4
184
334
484
Axis 2
Axis 3
Axis 4
1666
1766
1866
Axis 2
Axis 3
Axis 4
1628
1728
1828