Mitsubishi Electric MELSEC iQ-R-RD75P4 User Manual page 93

Melsec iq-r series positioning module (application)
Table of Contents

Advertisement

■Restrictions
In the following case, an error occurs and the positioning will not start. During the positioning control, the operation stops
immediately at the detection of the error.
• If the movement amount of each axis exceeds 1073741824 (= 2
speed specification method, Outside linear movement amount range (Error code: 1A15H) occurs at the start of the
positioning. (The maximum movement amount that can be set in [Da.6] Positioning address/movement amount is
30
1073741824 (= 2
).)
■Positioning data to be set
To use the 3-axis linear interpolation control (ABS linear 3), set the following positioning data.
: Always set, : Set as required, : Setting not required
Setting item
[Da.1]
Operation pattern
[Da.2]
Control method
[Da.3]
Acceleration time No.
[Da.4]
Deceleration time No.
[Da.5]
Axis to be interpolated
[Da.6]
Positioning address/movement amount
[Da.7]
Arc address
[Da.8]
Command speed
[Da.9]
Dwell time
[Da.10]
M code
[Da.27]
M code ON signal output timing
[Da.28]
ABS direction in degrees
[Da.29]
Interpolation speed specification method
For details on the settings, refer to the following.
Page 420 Positioning Data
• If Reference axis speed is used for the 3-axis linear interpolation control, set the major axis as the reference
axis. If the minor axis is set as the reference axis, the speed of the major axis cannot be suppressed with
[Pr.8] Speed limit value.
• For the combinations of the reference axis and interpolation axes, refer to the following.
Page 77 Interpolation control
30
) when 0: Composite speed is set in [Pr.20] Interpolation
Setting requirement of
reference axis
 (Set ABS linear 3.)
3 MAJOR POSITIONING CONTROL
Setting requirement of
interpolation axis
3.2 Positioning Data Setting
3
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents