Operation timing and the processing time
The following shows the details on the operation timing and processing time in the inching operation.
ON
Forward run JOG start
signal
OFF
[Y8, YA, YC, YE]
Reverse run JOG start
signal
OFF
[Y9, YB, YD, YF]
BUSY signal
OFF
[XC, XD, XE, XF]
Axis operation
Md.26
Standby
status
Pulse output to an external
source
(PULSE)
Positioning operation
Positioning complete
OFF
signal
[X14, X15, X16, X17]
Normal timing time
t1
1.0 to 3.0ms
ON
t1
t3
JOG operation
t2
t2
0.1ms or less
Standby
ON
t4
t3
0 to 0.88ms
t4
Depends on the parameter