Clearing Errors Or Warnings - Mitsubishi Electric MELSEC iQ-R-RD75P4 User Manual

Melsec iq-r series positioning module (application)
Table of Contents

Advertisement

Clearing errors or warnings

Eliminate the cause of an error or warning by referring to the actions described in the following, and clear the error or warning
using the error reset.
Page 523 List of Warning Codes
Page 527 List of Error Codes
Clearing errors/warnings by each axis
By setting 1 to the following buffer memory address of [Cd.5] Axis error reset, the error or warning is cleared after the
completion of the processing below.
Axis No.
1
2
3
4
■Processing
Error detection signal [X8, X9, XA, XB] is turned off.
[Md.23] Axis error No. is cleared.
[Md.24] Axis warning No. is cleared.
The value in [Md.26] Axis operation status changes from -1: Error to 0: Standby.
[Md.31] Status, Axis warning detection (b9) is turned off.
Clearing errors/warnings of all axes collectively
By setting 1 to [Cd.49] All axes error reset, errors or warnings of all axes are collectively cleared.
Axis No.
All axes
■Processing
Error detection signal [X8, X9, XA, XB] is turned off.
[Md.23] Axis error No. is cleared.
[Md.24] Axis warning No. is cleared.
The value in [Md.26] Axis operation status changes from -1: Error to 0: Standby.
[Md.31] Status, Axis warning detection (b9) is turned off.
14 TROUBLESHOOTING
522
14.3 Error and Warning Details
Buffer memory address ([Cd.5] Axis error reset)
1502
1602
1702
1802
Buffer memory address ([Cd.49] All axes error reset)
1933

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents