Block Start Data - Mitsubishi Electric MELSEC iQ-R-RD75P4 User Manual

Melsec iq-r series positioning module (application)
Table of Contents

Advertisement

12.5

Block Start Data

The following figure shows the configuration of the block start data stored in the buffer memory of the RD75.
2nd point
1st point
Setting item
b15
Da.11
Shape
b15
Da.13 Special start
instruction
2nd point
1st point
Setting item
b15
Da.11
Shape
b15
Da.13 Special start
instruction
The axis 3 and axis 4 have the same configuration.
12 DATA USED FOR POSITIONING CONTROL
434
12.5 Block Start Data
50th point
Setting item
Setting item
Buffer memory
address
b8
b7
b0
26000
Da.12 Start data No.
b8
b7
b0
26050
Da.14 Parameter
50th point
Setting item
Setting item
Buffer memory
address
b8
b7
b0
27000
Da.12 Start data No.
b8
b7
b0
27050
Da.14 Parameter
Buffer memory
address
Buffer memory
address
26049
26001
26099
26051
Buffer memory
address
Buffer memory
address
27049
27001
27099
27051
Up to 50 points of block start data for each axis can be set
(stored) in the buffer memory addresses shown on the left.
One block start data is configured of the items shown in
the bold box.
Each axis has five start blocks (block 0 to 4).