Creating a start program for the inching operation

To perform the inching operation, create a program. When creating a program, consider Control data requiring settings, Start
condition, and Start time chart. The following shows an example when the inching operation is started for the axis 1. ([Cd.16]
Inching movement amount is set to 10.0m.)
Control data requiring settings
The following control data must be set to execute the inching operation. The setting is executed with a program.
Setting item
[Cd.16]
Inching movement amount
For details on the settings, refer to the following.
Page 474 [Cd.16] Inching movement amount
Start condition
Satisfy the following conditions to start a program. In addition, set the required conditions in the program to prevent an
operation from starting if the conditions are not satisfied.
Signal name
Interface signal
PLC READY signal
RD75 READY signal
Module access flag
Axis stop signal
Start complete signal
BUSY signal
Positioning complete signal
Error detection signal
M code ON signal
External signal
Drive unit READY signal
Stop signal
Upper limit (FLS)
Lower limit (RLS)
*1 The interlock must be provided so that the buffer memory is accessed after Module access flag [X1] turns on. When no interlock is
provided, the buffer memory may be accessed while the module parameter and module extension parameter that are sent from the CPU
module are updated. If the buffer memory is accessed during the update, an unexpected value may be read or written.
5 MANUAL CONTROL
190
5.3 Inching Operation
Setting
Setting detail
value
100
Set a setting value so that the command pulse is not larger
than the maximum output pulse.
Maximum output pulse
RD75D: 5Mpulse/s
RD75P: 200kpulse/s
Signal status
ON
The CPU module is ready.
ON
RD75 READY signal
*1
ON
The RD75 buffer memory can be
accessed.
OFF
Axis stop signal is off.
OFF
Start complete signal is off.
OFF
The RD75 is not in operation.
OFF
Positioning complete signal is off.
OFF
No error has been detected.
OFF
M code ON signal is off.
ON
The drive unit is ready.
OFF
Stop signal is off.
ON
The current position is within the limit.
ON
The current position is within the limit.
Buffer memory address
Axis 1
Axis 2
Axis 3
1517
1617
1717
Device
Axis 1
Axis 2
Axis 3
Y0
X0
X1
Y4
Y5
Y6
X10
X11
X12
XC
XD
XE
X14
X15
X16
X8
X9
XA
X4
X5
X6
Axis 4
1817
Axis 4
Y7
X13
XF
X17
XB
X7