Mitsubishi Electric MELSEC iQ-R-RD75P4 User Manual page 432

Melsec iq-r series positioning module (application)
Table of Contents

Advertisement

[Da.8] Command speed
Set the command speed for positioning.
• When the set command speed exceeds the value set in [Pr.8] Speed limit value, positioning is performed at the speed limit
value.
• When the command speed is set to -1, the positioning control is performed at the current speed (speed set for previous
positioning data No.). Use the current speed for continuous path control and other controls. If -1 is set for continuing
positioning data, and the speed is changed, the following speed will also change. Note that when positioning starts, if the
speed -1 is set for the positioning data that performs positioning control first, No command speed (Error code: 1A12H)
occurs, and the positioning does not start.
■Buffer memory address
For the buffer memory address of this area, refer to the following.
Page 551 Positioning data
■Setting range
The setting range depends on the setting of [Pr.1] Unit setting.
Setting of [Pr.1] Unit setting
0: mm
1: inch
2: degree
3: pulse
*1 When this buffer memory area is set with programs, a calculation is performed in the RD75 to convert a setting value to the value in
each unit. For setting this buffer memory area, take the value after the unit conversion into consideration.
■Default value
The default value is 0 for all the axes.
12 DATA USED FOR POSITIONING CONTROL
430
12.4 Positioning Data
Setting value with engineering tools
0.01 to 20000000.00 (mm/min)
0.001 to 2000000.000 (inch/min)
0.001 to 3000000.000 (degree/min)
1 to 5000000 (pulse/s)
Setting value with programs
-2
1 to 2000000000 (10
mm/min)
-3
1 to 2000000000 (10
inches/min)
-3
1 to 3000000000 (10
degrees/min)
1 to 5000000 (pulse/s)
*1