1.2

Stopping

This section describes the stop control of the positioning. The following events may stop each positioning control by the
RD75.
• When each control ends normally
• When Drive unit READY signal (READY) is turned off
• When an error occurred in the CPU module
• When PLC READY signal [Y0] is turned off
• When an error occurs in the RD75
• When an operation is intentionally stopped (When a stop signal sent from the CPU module is turned on, or a stop signal
from an external device)
Stop processing
The stop controls are classified into three types: deceleration stop, sudden stop, and immediate stop. The following table
describes the stop controls (deceleration stop, sudden stop, and immediate stop) at the occurrence of each stop cause (When
the automatic deceleration control is performed).
Stop cause
Forced
Drive unit READY
stop
signal (READY) is
off
Fatal stop
Hardware stroke
(Stop
limit upper/lower
group 1)
limit error occurred
Emergency
CPU module error
stop (Stop
occurred
group 2)
PLC READY signal
[Y0] is off
Failure in the test
mode
Relatively
Axis error detection
safe stop
(errors other than
(Stop
the ones in stop
group 3)
group 1 and 2)
Error at operation
mode switching in
amplifier-less
*2
operation
Intentional
Stop signal turned
stop (Stop
on by an external
group 3)
device
Axis stop signal [Y4,
Y5, Y6, Y7] from the
CPU module is
turned on.
Stop signal from an
engineering tool
1 STARTING AND STOPPING
32
1.2 Stopping
Stop
M code
[Md.26]
axis
ON
Axis
signal
operation
after
status
stop
after stop
Each
Not
Error
axis
changed
Each
Not
Error
axis
changed
All
Not
Error
axes
changed
Turned
off
Not
changed
Each
Not
Error
axis
changed
*1
All
Not
Error
axes
changed
Each
Not
Stopped
axis
changed
(standby)
Stop processing
OPR control
Major
positioning
Machine
Fast
control
OPR
OPR
control
control
Immediate stop
Deceleration stop or sudden stop (Select with [Pr.37] Stop group 1
sudden stop selection.)
Deceleration stop or sudden stop (Select with [Pr.38] Stop group 2
sudden stop selection.)
Deceleration stop or sudden stop (Select with [Pr.39] Stop group 3
sudden stop selection.)
Advanced
Manual control
positioning
Inching
Manual
control
operation,
pulse
JOG
generator
operation
operation
Deceleration
stop
Deceleration
stop
Deceleration
stop
Deceleration
stop