Condition Start - Mitsubishi Electric MELSEC iQ-R-RD75P4 User Manual

Melsec iq-r series positioning module (application)
Table of Contents

Advertisement

Condition start

In Condition start, the condition judgment of the condition data specified in [Da.14] Parameter is performed for the positioning
data set in [Da.12] Start data No. If the conditions have been established, the block start data set as 1: Condition start is
executed. If the conditions have not been established, that block start data is ignored, and the block start data of the next point
will be executed.
The following shows setting examples and a control example in which Block start data and Positioning data are set as shown
in the setting examples.
Setting example
■Block start data settings
Axis 1 block start data
[Da.11] Shape
1st point
1: Continue
2nd point
1: Continue
3rd point
0: End
Condition data No. has been set in [Da.14] Parameter.
■Positioning data settings
Axis 1 positioning data
[Da.1] Operation pattern
No.
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
10
11: Continuous path control
11
11: Continuous path control
12
00: Positioning complete
50
00: Positioning complete
Control example
The following describes the control to be executed when the operation using the 1st point block start data of the axis 1 is
started.
Condition judgment target
(1)
The condition judgment set in Condition data No.1 is performed
before the execution of the positioning data No.1 of the axis 1.
(2)
The condition judgment set in Condition data No.2 is performed
before the execution of the positioning data No.10 of the axis 1.
(3)
-
[Da.12] Start data No.
[Da.13] Special start
instruction
1
1: Condition start
10
1: Condition start
50
0: Block start
Control details
• Conditions established: Positioning data No.1, 2, and 3 are executed and
processing proceeds on to (2).
• Conditions not established: Processing proceeds on to (2).
• Conditions established: Positioning data No.10, 11, and 12 are executed and
processing proceeds on to (3).
• Conditions not established: Processing proceeds on to (3).
The positioning data No.50 of Axis 1 is executed and processing stops.
[Da.14] Parameter
1
2
4 ADVANCED POSITIONING CONTROL
4.3 Setting the Block Start Data
4
161

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents