AudioCodes Mediant 3000 User Manual page 307

Enterprise session border controller / voip digital media gateway
Hide thumbs Also See for Mediant 3000:
Table of Contents

Advertisement

User's Manual
Parameter
Generate Digit On Time
[CasStateMachineGenerate
DigitOnTime]
Generate Inter Digit Time
[CasStateMachineGenerateI
nterDigitTime]
DTMF Max Detection Time
[CasStateMachineDTMFMa
xOnDetectionTime]
DTMF Min Detection Time
[CasStateMachineDTMFMin
OnDetectionTime]
MAX Incoming Address Digits
[CasStateMachineMaxNum
OfIncomingAddressDigits]
MAX Incoming ANI Digits
[CasStateMachineMaxNum
OfIncomingANIDigits]
Collet ANI
[CasStateMachineCollectA
NI]
Digit Signaling System
[CasStateMachineDigitSign
alingSystem]
Version 6.6
CAS State Machine Parameters Description
Generates digit on-time (in msec).
The value must be a positive value. The default is -1 (use value
from CAS state machine).
Generates digit off-time (in msec).
The value must be a positive value. The default is -1 (use value
from CAS state machine).
Detects digit maximum on time (according to DSP detection
information event) in msec units.
The value must be a positive value. The default is -1 (use value
from CAS state machine).
Detects digit minimum on time (according to DSP detection
information event) in msec units. The digit time length must be
longer than this value to receive a detection. Any number may be
used, but the value must be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default is -1 (use value
from CAS state machine).
Defines the limitation for the maximum address digits that need to
be collected. After reaching this number of digits, the collection of
address digits is stopped.
The value must be an integer. The default is -1 (use value from
CAS state machine).
Defines the limitation for the maximum ANI digits that need to be
collected. After reaching this number of digits, the collection of ANI
digits is stopped.
The value must be an integer. The default is -1 (use value from
CAS state machine).
In some cases, when the state machine handles the ANI collection
(not related to MFCR2), you can control the state machine to collect
ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value - use value from CAS state machine.
Defines which Signaling System to use in both directions
(detection\generation).
[0] DTMF = Uses DTMF signaling.
[1] MF = Uses MF signaling (default).
[-1] Default = Default value - use value from CAS state machine.
307
Description
21. Digital PSTN
Mediant 3000

Advertisement

Table of Contents
loading

Table of Contents