Signal
G1_ZSW.13
G1_ZSW.14
G1_ZSW.15
8.5
Signal sources for MELDW
The table below shows the definition of the message word MELDW.
Signal
MELDW.0
MELDW.1
MELDW.2
MELDW.3
MELDW.4
MELDW.5
MELDW.6
MELDW.7
MELDW.8
MELDW.9
MELDW.10
MELDW.11
MELDW.12
MELDW.13
MELDW.14
MELDW.15
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Description
Absolute value is cyclically transferred
Parking encoder active
Encoder fault, the fault is in Gn_XIST2
Description
1 = Ramp-up/ramp-down complete
0 = Ramp-function generator active
1 = Torque utilization [%] < torque threshold value 2
1 = |n_act| < speed threshold value 3 (p2161)
1 = |n_act| ≤ speed threshold value 2
1 = Vdc_min controller active
Reserved
1 = No motor overtemperature alarm
1 = No alarm, thermal overload, power unit
1 = Speed setpoint - actual value deviation within tolerance t_on
Reserved
Reserved
1 = Controller enable
1 = Drive ready
1 = Pulses enabled
Reserved
Reserved
PROFINET communication
8.5 Signal sources for MELDW
175