Siemens SIMOTICS S-1FL6 Operating Instructions Manual page 224

Sinamics / simotics
Hide thumbs Also See for SIMOTICS S-1FL6:
Table of Contents

Advertisement

Parameters
11.2 Parameter list
Par. No.
Name
p1663
Current setpoint filter 2
denominator natural fre-
quency
Description: Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1664
Current setpoint filter 2
denominator damping
Description: Sets the denominator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1665
Current setpoint filter 2
numerator natural fre-
quency
Description: Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1662 ... p1666.
p1666
Current setpoint filter 2
numerator damping
Description: Sets the numerator damping for current setpoint filter 2.
Dependency: Current setpoint filter 2 is activated via p1656.1 and parameterized via p1663 ... p1666.
p1668
Current setpoint filter 3
denominator natural fre-
quency
Description: Sets the denominator natural frequency for current setpoint filter 3 (PT2, general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1669
Current setpoint filter 3
denominator damping
Description: Sets the denominator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1670
Current setpoint filter 3
numerator natural fre-
quency
Description: Sets the numerator natural frequency for current setpoint filter 3 (general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1671
Current setpoint filter 3
numerator damping
Description: Sets the numerator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1673
Current setpoint filter 4
denominator natural fre-
quency
Description: Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1674
Current setpoint filter 4
denominator damping
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
224
Min
Max
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
0.5
16000.0
0.001
10.000
Factory
Unit
Data
Setting
type
1000.0
Hz
Float
0.300
-
Float
1000.0
Hz
Float
0.010
-
Float
1000.0
Hz
Float
0.300
-
Float
1000.0
Hz
Float
0.010
-
Float
1000.0
Hz
Float
0.300
-
Float
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U