Status words when telegrams 102 and 105 are used
● Status word ZSW1
● Status word ZSW2
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Signal
Description
ZSW1.0
1 = Ready for servo on
ZSW1.1
1 = Ready for operation
ZSW1.2
1 = Operation enabled
ZSW1.3
1 = Fault present
ZSW1.4
1 = No coast down active (OFF2 inactive)
ZSW1.5
1 = No fast stop active (OFF3 inactive)
ZSW1.6
1 = Switching on inhibited active
ZSW1.7
1 = Alarm present
ZSW1.8
1 = Speed setpoint - actual value deviation within tolerance t_off
ZSW1.9
1 = Control requested
ZSW1.10
1 = f or n comparison value reached/exceeded
ZSW1.11
1 = Alarm class bit 0
ZSW1.12
1 = Alarm class bit 1
ZSW1.13
Reserved
ZSW1.14
1 = Closed-loop torque control active
ZSW1.15
Reserved
Signal
Description
ZSW2.0
Reserved
ZSW2.1
Reserved
ZSW2.2
Reserved
ZSW2.3
Reserved
ZSW2.4
1 = Ramp-function generator inactive
ZSW2.5
1 = Open the holding brake
ZSW2.6
1 = Integrator inhibit, speed controller
ZSW2.7
Reserved
ZSW2.8
1 = Traverse to fixed endstop
ZSW2.9
Reserved
ZSW2.10
Reserved
ZSW2.11
Reserved
ZSW2.12
Slave sign-of-life, bit 0
ZSW2.13
Slave sign-of-life, bit 1
ZSW2.14
Slave sign-of-life, bit 2
ZSW2.15
Slave sign-of-life, bit 3
PROFINET communication
8.3 Control word STW and status word ZSW
171

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v90

Table of Contents