Par. No.
Name
r8939
PROFIdrive: Device access point (DAP) ID
Description: Displays the PROFINET device access point ID for the onboard PROFINET interface.
The combination of device ID (r8909) and DAP ID uniquely identifies a PROFINET access point.
r29018[0...
OA version
1]
Description: Displays the OA version.
Index:
[0]: Firmware version
•
[1]: Build increment number
•
r29400
Internal control signal status indicating
Description: Control signal status identifiers
The bits of the parameter are reseved except the following ones:
Bit 1: RESET
•
Bit 2: CWL
•
Bit 3: CCWL
•
Bit 10: TLIM
•
Bit 19: SLIM
•
Bit 23: REF
•
Bit 28: EMGS
•
r29942
DO signals status indicating
Description: Indicates the status of DO signals.
Bit 0: RDY
•
Bit 1: FAULT
•
Bit 2: Reserved
•
Bit 3: ZSP
•
Bit 4: Reserved
•
Bit 5: TLR
•
Bit 6: Reserved
•
Bit 7: MBR
•
Bit 8: OLL
•
Bit 9: Reserved
•
Bit 10: Reserved
•
Bit 11: Reserved
•
Bit 12: Reserved
•
Bit 13: RDY_ON
•
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Parameters
11.2 Parameter list
Unit
Data type
-
U32
-
Float
-
U32
-
U32
249