Parameters
11.2 Parameter list
Par. No.
Name
Description: Sets a fixed setpoint for the deceleration override.
Dependency: Refer to: p2572
Note: The percentage value refers to the maximum deceleration (p2573).
p8920[0...
PROFIdrive: Name of
239]
station
Description: Sets the station name for the onboard PROFINET interface on the Control Unit.
The active station name is displayed in r8930.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8921[0...
PROFIdrive: IP address
3]
of station
Description: Sets the IP address for the onboard PROFINET interface on the Control Unit.
The active IP address is displyed in r8931.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8922[0...
PROFIdrive: Default
3]
gateway of station
Description: Sets the default gateway for the onboard PROFINET interface on the Control Unit.
The active default gateway is displayed in r8932.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8923[0...
PROFIdrive: Subnet
3]
mask of station
Description: Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The active subnet mask is displayed in r8933.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8925
PROFIdrive: Interface
configuration
Description: Setting to activate the interface configuration for the onboard PROFINET interface on the Control
Unit.
p8925 is automatically set to 0 at the end of the operation.
p8925 = 0: No function
p8925 = 2: Save and activate configuration
The interface configuration (p8920 and following) is saved and activated after the next POWER ON.
p29000 *
Motor ID
Description: Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value. The range of
high inertia motor is 18 to 39; the range of low inertia motor is 42 to 71.
For a motor with an absolute encoder, the drive automatically reads the parameter value. The range of high
inertia motor with multi-turn encoder is 10009 to 10048.
p29001
Reversal of motor direc-
tion
234
Min
Max
-
-
0
255
0
255
0
255
0
3
0
65535
0
1
Factory
Unit
Data
Setting
type
-
-
U8
0
-
U8
0
-
U8
0
-
U8
0
-
U8
0
-
U16
0
-
I16
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T