PROFINET communication
8.4 Encoder control word and status word
Signal
G1_STW.6
G1_STW.7
G1_STW.8
G1_STW.9
G1_STW.10
G1_STW.11
G1_STW.12
G1_STW.13
G1_STW.14
G1_STW.15
The following table shows the definition of the encoder 1 status word G1_ZSW.
Signal
G1_ZSW.0
G1_ZSW.1
G1_ZSW.2
G1_ZSW.3
G1_ZSW.4
G1_ZSW.5
G1_ZSW.6
G1_ZSW.7
G1_ZSW.8
G1_ZSW.9
G1_ZSW.10
G1_ZSW.11
G1_ZSW.12
174
Description
Mode of the function to be activated
1 = Flying measurement
0 = Search for reference mark
Reserved
Reserved
Reserved
Reserved
Reserved
1 = Request value cyclic transfer of the absolute position value in Gn_XIST2
1 = Request parking encoder
= Acknowledge encoder fault
Description
Feedback signal of the active function (1 = function active)
1 = Position actual value from function 1
1 = Position actual value from function 2
1 = Position actual value from function 3
1 = Position actual value from function 4
1 = Measuring probe 1 deflected (high signal)
1 = Measuring probe 2 deflected (high signal)
Reserved
1 = Acknowledge encoder fault active
Reserved (for reference point offset)
Generated value in Gn_XIST2 (and can
be read)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002