Description: Sets the final rounding-off time for the extended ramp generator. The value applies to ramp-up
and ramp-down.
Note: Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
p1135
OFF3 ramp-down time
Description: Sets the ramp-down time from the maximum speed down to zero speed for the OFF3 command.
Note: This time can be exceeded if the DC link voltage reaches its maximum value.
p1215 *
Motor holding brake con-
figuration
Description: Sets the holding brake configuration.
Dependency: Refer to p1216, p1217, p1226, p1227, p1228
Caution: For the setting p1215 = 0, if a brake is used, it remains closed. If the motor moves, this will destroy
the brake.
Notice: If p1215 was set to 1, then when the pulses are suppressed, the brake is closed even if the motor is
still rotating.
Note: The parameter can only be set to zero when the pulses are inhibited.
p1216 *
Motor holding brake
opening time
Description: Sets the time to open the motor holding brake.
After controlling the holding brake (opens), the speed/velocity setpoint remains at zero for this time. After this,
the speed/velocity setpoint is enabled.
Dependency: Refer to p1215, p1217
Note: For a motor with integrated brake, this time is pre-assigned the value saved in the motor.
For p1216 = 0 ms, the monitoring and the message A7931 "Brake does not open" are deactivated.
p1217 *
Motor holding brake clos-
ing time
Description: Sets the time to apply the motor holding brake.
After OFF1 or OFF3 and the holding brake is controlled (the brake closes), then the drive remains closed-loop
controlled for this time stationary with a speed setpoint/velocity setpoint of zero. The pulses are suppressed
when the time expires.
Dependency: Refer to p1215, p1216
Note: For a motor with integrated brake, this time is pre-assigned the value saved in the motor.
For p1217 = 0 ms, the monitoring and the message A07932 "Brake does not close" are deactivated.
p1226
Threshold for zero speed
detection
Description: Sets the speed threshold for the standstill identification.
Acts on the actual value and setpoint monitoring. When braking with OFF1 or OFF3, when the threshold is
undershot, standstill is identified.
The following applies when the brake control is activated:
When the threshold is undershot, the brake control is started and the system waits for the brake closing time
in p1217. The pulses are then suppressed.
If the brake control is not activated, the following applies:
When the threshold is undershot, the pulses are suppressed and the drive coasts down.
Dependency: Refer to p1215, p1216, p1217, p1227
Notice: For reasons relating to the compatibility to earlier firmware versions, a parameter value of zero in
indices 1 to 31 is overwritten with the parameter value in index 0 when the drive boots.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Min
Max
0
600
0
2
0
10000
0
10000
0.00
210000.00
Factory
Unit
Data
Setting
type
0
s
Float
0
-
I16
100
ms
Float
100
ms
Float
20.00
rpm
Float
Parameters
11.2 Parameter list
Effective
Can be
changed
IM
T, U
IM
T
IM
T, U
IM
T, U
IM
T, U
219

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v90

Table of Contents