Resonance Suppression - Siemens SIMOTICS S-1FL6 Operating Instructions Manual

Sinamics / simotics
Hide thumbs Also See for SIMOTICS S-1FL6:
Table of Contents

Advertisement

Parameter settings
You need to set the following servo gains related parameters manually when using the
manual tuning function:
Parameter Value range
p2533
p2572
p2573
p29110
p29120
p29121
p29111
10.6

Resonance suppression

The resonance suppression function is filter (notch filter) function. It detects mechanical
resonance at a frequency between 250 Hz and 1500 Hz, and decreases the gain of specific
frequency (by automatically setting notch filter) to suppress the mechanical resonance.
Now four current setpoint filters are available for the V90 PN servo drive. Filter 1 is lowpass
filter. Filter 2, filter 3 and filter 4 are band damp filters.
The gain decreasing frequency, width as well as depth can be set by setting the notch filter:
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Default
Unit
value
0 to 1000
0
ms
1 to 2000000 100
1000
LU/s
1 to 2000000 100
1000
LU/s
0.00 to
1.8
1000/
300.00
min
0 to 999999
0.3
Nms/r
ad
0 to 100000
15
ms
0 to 200
0
%
Description
LR position setpoint filter time constant
EPOS maximum acceleration
2
EPOS maximum deceleration
2
Position loop gain
Speed loop gain
Speed loop integral time
Speed pre-control factor (feed forward)
Tuning
10.6 Resonance suppression