Parameters
11.2 Parameter list
Par. No.
Name
p2586
EPOS jog 2 setpoint
velocity
Description: Sets the setpoint speed for jog 2.
Dependency: Refer to: p2588
p2587
EPOS jog 1 traversing
distance
Description: Sets the traversing distance for incremental jog 1.
Dependency: Refer to: p2585
p2588
EPOS jog 2 traversing
distance
Description: Sets the traversing distance for incremental jog 2.
Dependency: Refer to: p2586
p2599
EPOS reference point
coordinate value
Description: Sets the position value for the reference point coordinate. This value is set as the actual axis
position after referencing or adjustment.
Dependency: Refer to: p2525
p2600
EPOS search for refer-
ence point offset
Description: Sets the reference point offset for search for reference.
p2604
EPOS search for refer-
ence start direction
Description: Sets the signal sources for the start direction of the search for reference.
1 signal: Start in the negative direction.
0 signal: Start in the positive direction.
Dependency: Refer to p2583
p2605
EPOS search for refer-
ence approach velocity
reference cam
Description: Sets the approach velocity to the reference cam for the search for reference.
Dependency: The search for reference only starts with the approach velocity to the reference cam when there
is a reference cam.
Refer to: p2604, p2606
Note: When traversing to the reference cam, the velocity override is effective. If, at the start of the search for
reference, the axis is already at the reference cam, then the axis immediately starts to traverse to the zero
mark.
p2606
EPOS search for refer-
ence reference cam max-
imum distance
Description: Sets the maximum distance after the start of the search for reference when traversing to the
reference cam.
Dependency: Refer to: p2604, p2605, and F07458
230
Min
Max
-40000000
40000000
0
214748264
7
0
214748264
7
-2147482648
214748264
7
-2147482648
214748264
7
-
-
1
40000000
0
214748264
7
Factory
Unit
Data
Setting
type
300
100
I32
0 L
U/mi
n
1000
LU
U32
1000
LU
U32
0
LU
I32
0
LU
I32
0
-
U32/Bina
ry
5000
100
U32
0 L
U/mi
n
214748
LU
U32
2647
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T, U
IM
T, U

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v90

Table of Contents