Siemens SIMOTICS S-1FL6 Operating Instructions Manual page 73

Sinamics / simotics
Hide thumbs Also See for SIMOTICS S-1FL6:
Table of Contents

Advertisement

NOTICE
Drive damage caused by short-circuiting between the shielding wire and the unused pin on
the PROFINET I/O connector
The shielding wire may inadvertently be short-circuited to the unused pin on the to-be-
assembled PROFINET I/O connector. This can cause damage to the drive.
Exercise caution when connecting the shielding cable to the PROFINET I/O connector.
You can see the assembly method of the connector in Section "Assembly of cable
terminals on the drive side (Page 283)".
Note
Low Voltage Directive complied
Our products comply with EN61800-5-1: 2007 standards and Low Voltage Directive (Low
Voltage Directive 2006/95/EC).
Note
For low inertia motors of shaft heights 20 mm, 30 mm and 40 mm, the encoder cable
connectors may only be accessible to electrically skilled personnel.
Note
The mini-USB interface of the SINAMICS V90 PN is used for fast commissioning and
diagnostics with SINAMICS V-ASSISTANT installed in the PC. Do not use it for long
monitoring.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 09/2016, A5E37208830-002
Connecting
4.1 System connection
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v90

Table of Contents