Setpoint Menu Overview - GE F650 Instruction Manual

Digital bay controller
Hide thumbs Also See for F650:
Table of Contents

Advertisement

4.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE 4 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES
Table 4.5: GENERAL OVERVIEW OF SETPOINT MENU IN ENERVISTA 650 SETUP:
SETPOINT
4
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
4.1.8.1 PRODUCT SETUP
Table 4.6: GENERAL OVERVIEW OF PRODUCT SETUP MENU:
PRODUCT
SETUP
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
a) COMMUNICATION SETTINGS
This section details the settings related to communication parameters for the different protocols available in the F650.
4-16
Communications settings for all protocols and physical mediums.
Product Setup
ModBus user map definition, fault report, oscillography, data logger and
demand settings.
General Settings, Flex Curves Definition, Breaker settings and
System Setup
maintenance, and switchgear snapshot events management.
Phase, Neutral, Ground, Sensitive Ground and Negative Sequence
Protection Elements
Current Settings. Voltage Elements settings and Power Settings
management.
Setting groups, under and overfrequency settings, synchrocheck,
Control Elements
autoreclose, breaker failure, VT fuse failure, broken conductor and
locked rotor settings management.
Inputs/Outputs
Contact I/O settings for all boards available in device, Remote Comms.
Configuration of Outputs, LEDs, Operations, Protection Elements,
Oscillography, Control Events, Switchgear, Inputs, Virtual Inputs,
Relay Configuration
Operations and HMI. Whole relay configuration with internal relay signals
or user-definable ones as logic (virtual outputs).
Logic configuration graphic editor (PLC Editor). It is a PLC Project file
editor that contains all the internal drawings used to make the logic
Logic Configuration
(virtual outputs) based on IEC 61131-3 standard. Functional block
diagram (FDB).
61850 Configuration tool. Only available for IEC61850 models (6) when
61850 Configuration
communicating through Ethernet with EnerVista 650 Setup.
Procome Configuration tool. Only available for Procome models (5)
Procome Configuration
when communicating through Ethernet with EnerVista 650 Setup
IEC103 settings for available IEC103 models (3) when communicating
IEC103 Configuration
through Ethernet with Enervista 650 Setup
Relay synchronization to computer clock or to user-definable date and
Clock (*)
time. On-line mode only.
Communication
Serial Ports, Network (Ethernet), ModBus Protocol, DNP Slave, IEC 870-
Settings
5-104, SNTP settings and procome (if available on model selection).
ModBus user map definition. The ModBus user map is formed by 256
ModBus User Map
records, selectable from the complete relay ModBus map.
Fault Report
Fault report settings. Possibility to show fault reports on HMI screen.
Oscillography settings (trigger position, samples per cycle, etc.). The
Oscillography
trigger and digital channels (up to 16) must be configured in
"Setpoint>Relay configuration".
Data Logger
Data logger configuration
Demand settings. The demand trigger and demand reset signals must be
Demand
configured in "Setpoint>Relay configuration"
Time Settings
Time settings for SNTP & IRIG-B
F650 Digital Bay Controller

4.1.8 SETPOINT MENU OVERVIEW

GEK-106310AB