Setpoint Menu Overview - GE Multilin GEK-113000T User Manual

Digital bay controller
Table of Contents

Advertisement

3 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE
Table 3–5: GENERAL OVERVIEW OF SETPOINT MENU IN ENERVISTA 650 SETUP:
SETPOINT
Product Setup
System Setup
Protection Elements
Control Elements
Inputs/Outputs
Relay Configuration
Logic Configuration
61850 Configuration
Procome Configuration
Clock (*)
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
3.1.8.1 PRODUCT SETUP
Table 3–6: GENERAL OVERVIEW OF PRODUCT SETUP MENU:
PRODUCT
SETUP
Communication
Settings
ModBus User Map
Fault Report
Oscillography
Data Logger
Demand
Options enabled only in On-line mode are marked as (*). Options enabled only in Off-line mode are marked as (**)
a) COMMUNICATION SETTINGS
This section details the settings related to communication parameters for the different protocols available in the F650.
GEK-113000T
Communications settings for all protocols and physical mediums.
ModBus user map definition, fault report, oscillography, data logger and
demand settings.
General Settings, Flex Curves Definition, Breaker settings and
maintenance, and switchgear snapshot events management.
Phase, Neutral, Ground, Sensitive Ground and Negative Sequence
Current Settings. Voltage Elements settings and Power Settings
management.
Setting groups, under and overfrequency settings, synchrocheck,
autoreclose, breaker failure, VT fuse failure, broken conductor and
locked rotor settings management.
Contact I/O settings for all boards available in device, Remote Comms.
Configuration of Outputs, LEDs, Operations, Protection Elements,
Oscillography, Control Events, Switchgear, Inputs, Virtual Inputs,
Operations and HMI. Whole relay configuration with internal relay signals
or user-definable ones as logic (virtual outputs).
Logic configuration graphic editor (PLC Editor). It is a PLC Project file
editor that contains all the internal drawings used to make the logic
(virtual outputs) based on IEC 61131-3 standard. Functional block
diagram (FDB).
61850 Configuration tool. Only available for IEC61850 models (6) when
communicating through Ethernet with EnerVista 650 Setup.
Procome Configuration tool. Only available for Procome models (5)
when communicating through Ethernet with EnerVista 650 Setup
Relay synchronization to computer clock or to user-definable date and
time. On-line mode only.
Serial Ports, Network (Ethernet), ModBus Protocol, DNP Slave, IEC 870-
5-104, SNTP settings and procome (if available on model selection).
ModBus user map definition. The ModBus user map is formed by 256
records, selectable from the complete relay ModBus map.
Fault report settings. Possibility to show fault reports on HMI screen.
Oscillography settings (trigger position, samples per cycle, etc.). The
trigger and digital channels (up to 16) must be configured in
"Setpoint>Relay configuration".
Data logger configuration
Demand settings. The demand trigger and demand reset signals must be
configured in "Setpoint>Relay configuration"
F650 Digital Bay Controller

3.1.8 SETPOINT MENU OVERVIEW

3
3-15