GE IC3645SH7R354D1 Installation And Operation Manual
GE IC3645SH7R354D1 Installation And Operation Manual

GE IC3645SH7R354D1 Installation And Operation Manual

Separately excited (sx) transistorized motor controllers for neighborhood electric vehicle application

Advertisement

Quick Links

INSTALLATION AND OPERATION
SX TRANSISTOR CONTROL
SEPARATELY EXCITED (SX) TRANSISTORIZED MOTOR CONTROLLERS
Note: The information contained herein is intended to assist OEM's, Dealers and Users of electric vehicles in the application,
installation and service of GE solid-state controllers. This manual does not purport to cover all variations in OEM vehicle types.
Nor does it provide for every possible contingency to be met involving vehicle installation, operation or maintenance. For
additional information and/or problem resolution, please refer the matter to the OEM vehicle manufacturer through his normal
field service channels. Do not contact GE directly for this assistance.
Section 1.0
INTRODUCTION ........................................................................................................................................................ 3
1.1
1.2
1.3
1.4
Section 2.0
FEATURES OF SX FAMILY OF MOTOR CONTROLLERS .................................................................................... 5
2.1
2.1.1
2.1.1.a
2.1.1.b
2.1.2
2.1.3
2.1.4
2.1.4.a
2.1.4.b
2.1.4.c
2.1.5
2.1.6
FOR NEIGHBORHOOD ELECTRIC VEHICLE APPLICATION
INSTALLATION AND OPERATION MANUAL
(GE MODEL IC3645SH7R354D1)
General Electric Company July 2001
Table of Contents
Motor Characteristics .............................................................................................................. 3
Solid-State Reversing ............................................................................................................... 4
Flexible System Application..................................................................................................... 4
More Features with Fewer Components ................................................................................ 4
Performance.............................................................................................................................. 5
Oscillator Card Features .................................................................................................. 5
Standard Operation................................................................................................... 5
Control Acceleration ................................................................................................ 5
Current Limit ...................................................................................................................... 5
Plug Braking ...................................................................................................................... 5
Auxiliary Speed Control.................................................................................................... 5
Field Weakening........................................................................................................ 5
Speed Limits .............................................................................................................. 5
Top Speed Regulation .............................................................................................. 5
Ramp Start ......................................................................................................................... 6
On-Board Coil Drivers and Internal Coil Suppression ................................................. 6
Page 1
July 2001

Advertisement

Table of Contents
loading

Summary of Contents for GE IC3645SH7R354D1

  • Page 1 Note: The information contained herein is intended to assist OEM's, Dealers and Users of electric vehicles in the application, installation and service of GE solid-state controllers. This manual does not purport to cover all variations in OEM vehicle types. Nor does it provide for every possible contingency to be met involving vehicle installation, operation or maintenance. For additional information and/or problem resolution, please refer the matter to the OEM vehicle manufacturer through his normal field service channels.
  • Page 2: Table Of Contents

    Recommended Lubrication of Pins and Sockets Prior to Installation........14 General Troubleshooting Instructions ................... 15 Traction Controller Status Codes ....................16-27 Section 5.0 SX FAMILY - GE HANDSET INSTRUCTIONS ...................... 28 General Features ........................28 Purpose/Setup Functions ......................28 Setup Function Procedures ....................29 5.3.1...
  • Page 3 SPEED new advances on the horizon. GE has introduced a second generation system using separately excited DC shunt wound motors. The separately excited DC motor system offers many of the features that are generally found on the advanced AC systems.
  • Page 4 For GE, the future is now, as we make available a new problems that would cause a full motor torque condition.
  • Page 5 This top speed function (Minimum Field Current) is enabled setting will be determined by GE and OEM engineers at the when the armature current is less than the value set by time of vehicle development.
  • Page 6: System Protective Override

    BASIC OPERATION AND FEATURES SX TRANSISTOR CONTROL Page 6 the level surface, the control automatically transitions back Section 2.2.4 Thermal Protector (TP) to the normal running mode. This temperature sensitive device is internal to the power Section 2.1.5 Ramp Start transistor (Q1) module.
  • Page 7: Hourmeter Readings

    BDI. Section 2.3.5 Handset This is a multi-functional tool used with the LX, ZX, and SX Series GE solid state controls. The Handset consists of a Light Emitting Diode (LED) display and a keyboard for data entry.
  • Page 8: Ordering Information, Elementary And Outline Drawings

    OUTLINE DRAWINGS, ELEMENTARY DRAWINGS AND INPUTS/OUTPUTS SX TRANSISTOR CONTROL Page 8 Section 3.0 ORDERING INFORMATION, ELEMENTARY AND OUTLINE DRAWINGS Section 3.1 Ordering Information for Separately Excited Controls Example: Part Number: IC3645 Argument Number: Argument 01: Basic Electric Vehicle Control Number Argument 02: Control Type: Separately Excited Control ( Plugging )
  • Page 9: Outline: Sx-2 Package Size

    OUTLINE DRAWINGS, ELEMENTARY DRAWINGS AND INPUTS/OUTPUTS SX TRANSISTOR CONTROL Page 9 Section 3.2 Outline: SX-2 Package Size July 2001...
  • Page 10: Standard Elementary For Nev Application

    ELEMENTARY DRAWING FOR TYPICAL SEPARATELY EXCITED TRACTION MOTOR CONTROLLER FOR NEV APPLICATIONS FU3 * CHARGER SWITCH * KEY SWITCH * DIRECTIONAL LINE * FU1 * SWITCH * 400A P2 P3 P21 P11 P10 PLUG (23 PIN) +12V P15 P14 P7 P9 P13 P8 P6 POWER CONNECTIONS TO CONTROL...
  • Page 11: Standard Nev Application Input/Output List

    OUTLINE DRAWINGS, ELEMENTARY DRAWINGS AND INPUTS/OUTPUTS SX TRANSISTOR CONTROL Page 11 Section 3.4 Standard Neighborhood Electric Vehicle Application Input/Output List Connections to Main Plug (23 Pin) and “Y” Plug (8 Pin) MAIN PLUG INPUT/OUTPUT DESCRIPTION BATTERY VOLTS FROM BATTERY BATTERY VOLTS FROM KEY 12 VOLT INPUT FROM ACCELERATOR START SWITCH 12 VOLT INPUT FROM FORWARD SWITCH 12V VOLT INPUT FROM REVERSE SWITCH...
  • Page 12: Troubleshooting And Diagnostic Status Codes

    The semiconductor junctions have finite temperature limits, above which these devices GE does not recommend that any type of welding be may be damaged. For these reasons, normal maintenance performed on the vehicle after the installation of the should guard against any action which will expose the control(s) in the vehicle.
  • Page 13: High Level Signals (Level H)

    DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 13 •= Control common tie customer must apply the general guidelines (section •= DC buses feeding sensitive analog or digital hardware 4.2.3.a), outlined below. •= All wiring connected to components associated with 4.2.3.a General Cable Spacing sensitive analog hardware with less than 5V signals (for example, potentiometers and tachometers) •= Digital tachometers and resolvers...
  • Page 14: Recommended Lubrication Of Pins And Sockets Prior To Installation

    EV100/EV200 and Gen II products. Any connection made by Clean each terminal using Chemtronics contact GE to the A, B, X, Y, or Z plugs, includes the lubricant NYE cleaner “Pow-R-WasH CZ “ as shown in Figure 1. 760G to prevent fretting of these connections during vehicle operation.
  • Page 15: General Troubleshooting Instructions

    DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 15 Section 4.4 General Troubleshooting Instructions Trouble-shooting the ZX family of controls should be quick and easy when following the instructions outlined in the following status code instruction sheets. If mis-operation of the vehicle occurs, a status code will be displayed on the Dash Display (for vehicles equipped with a Dash Display) or made available by plugging a Handset into the plug "Y"...
  • Page 16: Traction Controller Status Codes

    DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 16 Section 4.5 Traction Control Codes TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Segments do not illuminate on the No input voltage to the control card or the display unit. NONE Dash Display and/or the Handset.
  • Page 17 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 17 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE The accelerator pedal is depressed with This status code will be displayed when the no direction selected. accelerator voltage, at P7>1.5V, and no direction is selected (P4 and P5 are both less than 7.2V) MEMORY RECALL CORRECTIVE ACTIONS...
  • Page 18 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 18 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Both the forward and reverse switches This status code will be displayed when P4 and P5 are closed at the same time. are less than 7.2 volts, and P7 is less than 2.5 volts.
  • Page 19 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 19 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Battery voltage is too low at initial key switch This status code will be displayed when the closure. battery volts are less than 68.3 volts at initial key switch on.
  • Page 20 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 20 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Accelerator voltage is too high. This status code will be displayed when the accelerator voltage at P7 is greater than 4.5 volts. MEMORY RECALL CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM...
  • Page 21 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 21 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Motor field current is too high on when This status code will be displayed when the current the start switch is closed and the draw in the motor field is too high on start up in the forward direction is selected.
  • Page 22 (Values of greater than 4 V at the thermal protector are typically indicative of a failed control.) GE Sentry for Windows software can be used to monitor control operation, and it will display a value for the thermal protector that is greater than 84 (corresponding to 1.65V), triggering this...
  • Page 23 Defective control. •= Replace controller unit. Controller GE Sentry for Windows software can be used to monitor control operation, and it will display a value for the motor amps that is less than 117 (corresponding to 2.3V), triggering this status code.
  • Page 24 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 24 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Armature transistor did not turn on This status code will be displayed when, during properly. control operation, the armature transistor fails to turn on properly.
  • Page 25 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 25 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Motor field current is too low during the This status code will be displayed when the current run mode. draw in the motor field is less than 1.3 amps and armature current is greater than 100 amps for more than 1.27 seconds during the run mode.
  • Page 26 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 26 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Controller “motor current sensor” input This status code will be displayed when the voltage is too low during running. input from the current sensor is too low (less than 1.43V, -350 amps) during running.
  • Page 27 DIAGNOSTIC STATUS CODES SX TRANSISTOR CONTROL Page 27 TRACTION DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION STATUS CODE Capacitor (1C) voltage too high during This status code will be displayed when the voltage at regenerative braking. 1C exceeds 96 volts during the regenerative braking cycle.
  • Page 28: Sx Family - Ge Handset Instructions

    START-UP DISPLAY SEQUENCE Section 5.1 General Features Key Switch On The GE Handset is a multi-functional tool to be used with the LX, ZX, and SX Series GE solid-state controls. The Handset consists of a Light Emitting Diode (LED) display Verify Each LED Segment and a keyboard for data entry.
  • Page 29: Setup Function Procedures

    This will place you in the setup mode, ready to monitor or adjust control function settings. ACCESSING STORED STATUS CODES NOTE: The term “Push” means to depress key for WITH GE HANDSET approximately one second. Key Switch Off Section 5.3.1 Setup Mode...
  • Page 30: Setup Functions For Traction Controller

    Important Note: The function is used to optimize motor and control performance and this setting will be determined by GE and OEM engineers at the time of vehicle development. This setting must not be changed by field personnel without the permission of the OEM.
  • Page 31 GE and OEM engineers at the time of vehicle development. GE and OEM engineers at the time of vehicle development. This setting must not be changed by field personnel without This setting must not be changed by field personnel without the permission of the OEM.
  • Page 32 ADJUSTABLE FEATURES SX TRANSISTOR CONTROLS Page 32 Range 100% to 0% of battery volts 2.54 0.95 51 to 170 2.28 0.91 Resolution 0.78% per set unit 2.08 0.88 Example: Setting of 0 = no speed limit 1.90 0.85 Setting of 170 = maximum speed 1.76 0.82 reduction...
  • Page 33 Important Note: The function is used to optimize motor and REGEN/PLUGGING control performance and this setting will be determined by GE and OEM engineers at the time of vehicle development. ( Push CONT 4 ) This setting must not be changed by field personnel without the permission of the OEM.
  • Page 34 ADJUSTABLE FEATURES SX TRANSISTOR CONTROLS Page 34 FUNCTION 30 HOUR METER THOUSANDS FUNCTION 27 HOUR METER MINUTES (Push CONT 12) AND HUNDREDS HOURS SET ( Push CONT 15) This function adjusts the number of 30 second intervals This function allows for the adjustment of the thousands registering in the hour meter.
  • Page 35: Summary Of Current Limit Adjustments

    The value for this function will be defined by the GE application engineer. The " minimum field current" setting is adjusted by Function 7. The function sets the top speed of the motor.
  • Page 36: Memory Map

    Error Compensation HS or PC None Field Weakening Start HS or PC None Monitor HS or PC GE Temporary Storage Ratio of Field to Armature Amps HS or PC None Hour Meter Minutes HS or PC None Fault Count Pointer...
  • Page 37 RS-232 MEMORY MAP TABLES SX TRANSISTOR CONTROL Page 37 Func No. Traction Control Access By Restrictions Function BDI 4 PC Only Reset to Zero Only Hours (Tens/Ones) 4 PC Only Reset to Zero Only Hours (Thou/Hun) 4 PC Only Reset to Zero Only (26) Stored Status Code #5 PC Only...
  • Page 38 OEM Read Only Secure Aux HM (Tens/Ones) PC Only OEM Read Only Secure Aux HM (Thou/Hun) PC Only OEM Read Only Reserved PC Only GE Future Use Reserved PC Only GE Future Use Reserved PC Only GE Future Use Reserved PC Only...

Table of Contents