Rate   L imiter   I D:  
Select   which   rate   limiter   to   apply   on   this   port.   The   allowed   values   are   Disabled   or   the   values   1  
through   1 6.   T he   d efault   v alue   i s   " Disabled".    
Port   R edirect:  
Select   which   port   frames   are   redirected   on.   The   allowed   values   are   Disabled   for   a   specific   port  
number   a nd   i t   c an't   b e   s et   w hen   a ction   i s   p ermitted.   T he   d efault   v alue   i s   " Disabled".    
Mirror:  
Specify   t he   m irror   o peration   o f   t his   p ort.   T he   a llowed   v alues   a re:    
Enabled:   F rames   r eceived   o n   t he   p ort   a re   m irrored.    
Disabled:   F rames   r eceived   o n   t he   p ort   a re   n ot   m irrored.    
The   d efault   v alue   i s   " Disabled".    
Logging:  
Specify   t he   l ogging   o peration   o f   t his   p ort.   T he   a llowed   v alues   a re:    
Enabled:   F rames   r eceived   o n   t he   p ort   a re   s tored   i n   t he   S ystem   L og.    
Disabled:   F rames   r eceived   o n   t he   p ort   a re   n ot   l ogged.    
The  default  value  is  "Disabled".  Please  note  that  the  System  Log  memory  size  and  logging  rate  is  
limited.    
Shutdown:  
Specify   t he   p ort   s hut   d own   o peration   o f   t his   p ort.   T he   a llowed   v alues   a re:    
Enabled:   I f   a   f rame   i s   r eceived   o n   t he   p ort,   t he   p ort   w ill   b e   d isabled.  
Disabled:   P ort   s hut   d own   i s   d isabled.  
The   d efault   v alue   i s   " Disabled".    
State:  
Specify   t he   p ort   s tate   o f   t his   p ort.   T he   a llowed   v alues   a re:    
Enabled:   T o   r eopen   p orts   b y   c hanging   t he   v olatile   p ort   c onfiguration   o f   t he   A CL   u ser   m odule.    
Disabled:   T o   c lose   p orts   b y   c hanging   t he   v olatile   p ort   c onfiguration   o f   t he   A CL   u ser   m odule.    
The   d efault   v alue   i s   " Enabled."    
Counter:  
Counts   t he   n umber   o f   f rames   t hat   m atch   t his   A CE.    
Buttons  
Apply   –   C lick   t o   s ave   c hanges.  
  Reset-­‐   C lick   t o   u ndo   a ny   c hanges   m ade   l ocally   a nd   r evert   t o   p reviously   s aved   v alues.
Upper   r ight   i con   ( Refresh,   c lear)    
Click   o ne   o f   t hese   i cons   t o   r efresh   t he   A CL   P ort   C onfiguration   o r   c lear   i t   m anually.  