I Pmc   P Rofile   R Ule   S Ettings   T Able - Black Box LPB2910A User Manual

Lpb2900 series gigabit managed poe+ switches
Hide thumbs Also See for LPB2910A:
Table of Contents

Advertisement

 
 
Parameter   d escription:  
Port:  
The   s witch   p ort   n umber   o f   t he   c orresponding   S TP   C IST   ( and   M STI)   p ort.    
Global   P rofile   M ode  
Enable/Disable   t he   G lobal   I PMC   P rofile.  
System   s tarts   t o   d o   f iltering   b ased   o n   p rofile   s ettings   o nly   w hen   t he   g lobal   p rofile   m ode   i s   e nabled.    
Delete  
Check   t o   d elete   t he   e ntry.  
The   d esignated   e ntry   w ill   b e   d eleted   d uring   t he   n ext   s ave.    
Profile   N ame  
The   n ame   u sed   f or   i ndexing   t he   p rofile   t able.  
Each   e ntry   h as   t he   u nique   n ame   t hat   i s   c omposed   o f   a   m aximum   1 6   a lphabetic   a nd   n umeric  
characters.   A t   l east   o ne   a lphabetic   c haracter   m ust   b e   p resent.    
Profile   D escription  
Additional   d escription,   w hich   i s   c omposed   o f   a   m aximum   o f   6 4   a lphabetic   a nd   n umeric   c haracters,  
about   t he   p rofile.  
No   b lank   o r   s pace   c haracters   a re   p ermitted   a s   p art   o f   d escription.   U se   " _"   o r   " -­‐"   t o   s eparate   t he  
description   s entence.    
Rule  
When   t he   p rofile   i s   c reated,   c lick   t he   e dit   b utton   t o   e nter   t he   r ule   s etting   p age   o f   t he   d esignated  
profile.   A   s ummary   a bout   t he   d esignated   p rofile   w ill   b e   s hown   b y   c licking   t he   v iew   b utton.   Y ou   c an  
manage   o r   i nspect   t he   r ules   o f   t he   d esignated   p rofile   b y   u sing   t he   f ollowing   b uttons:    
:   L ist   t he   r ules   a ssociated   w ith   t he   d esignated   p rofile.    
:   A djust   t he   r ules   a ssociated   w ith   t he   d esignated   p rofile.    
Buttons  
Add   N ew   I PMC   P rofile   –   C lick   t o   a dd   n ew   I PMC   p rofile.   S pecify   t he   n ame   a nd   c onfigure   t he   n ew  
entry.   C lick   " Save."  
Apply   –   C lick   t o   s ave   c hanges.  
Reset   –   C lick   t o   u ndo   a ny   c hanges   m ade   l ocally   a nd   r evert   t o   p reviously   s aved   v alues.  
 
2-­‐9.1.1   I PMC   P rofile   R ule   S ettings   T able  
This   p age   p rovides   t he   f iltering   r ule   s ettings   f or   a   s pecific   I PMC   p rofile.   I t   d isplays   t he   c onfigured   r ule  
entries  in  precedence  order.  The  first  rule  entry  has  the  highest  priority  in  lookup,  while  the  last  rule  
entry   h as   t he   l owest   p riority   i n   l ookup.  
Profile   N ame  
The   n ame   o f   t he   d esignated   p rofile   t o   b e   a ssociated.   T his   f ield   i s   n ot   e ditable.    
111
Publication date: Sept, 2015
Revision A1
 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpb2926aLpb2952a

Table of Contents