Parameter
d escription:
Optimize
E EE
f or
The
s witch
c an
b e
s et
t o
o ptimize
E EE
f or
e ither
b est
p ower
s aving
o r
l east
t raffic
l atency.
Port:
The
s witch
p ort
n umber
o f
t he
l ogical
p ort.
ActiPHY:
Link
d own
p ower
s avings
e nabled.
ActiPHY
w orks
b y
l owering
t he
p ower
f or
a
p ort
w hen
t here
i s
n o
l ink.
T he
p ort
i s
p owered
o n
f or
a
short
m oment
t o
d etermine
i f
c able
i s
i nserted.
PerfectReach:
Cable
l ength
p ower
s avings
e nabled.
PerfectReach
works
by
determining
the
cable
length
and
lowering
the
power
for
ports
with
short
cables.
EEE:
Controls
w hether
E EE
i s
e nabled
f or
t his
s witch
p ort.
To
maximize
power
savings,
the
circuit
isn't
started
once
transmit
data
is
ready
for
a
port,
but
is
instead
q ueued
u ntil
a
b urst
o f
d ata
i s
r eady
t o
b e
t ransmitted.
T his
w ill
g ive
s ome
t raffic
l atency.
You
can
minimize
the
latency
for
specific
frames
by
mapping
the
frames
to
a
specific
queue
(done
with
QOS),
and
then
marking
the
queue
as
an
urgent
queue.
When
an
urgent
queue
gets
data
to
be
transmitted,
the
circuits
will
be
powered
up
and
the
latency
will
be
reduced
to
the
wakeup
time.
EEE
U rgent
Q ueues:
Queues
set
will
activate
transmission
of
frames
as
soon
as
data
is
available.
Otherwise,
the
queue
will
p ostpone
t ransmission
u ntil
a
b urst
o f
f rames
c an
b e
t ransmitted.
16
Publication date: Sept, 2015