3-­‐5.4.1.3   A larm  
This   p age   p rovides   a n   o verview   o f   R MON   A larm   e ntries.   E ach   p age   s hows   u p   t o   9 9   e ntries   f rom   t he  
Alarm   t able,   d efault   i s   2 0,   s elected   t hrough   t he   " entries   p er   p age"   i nput   f ield.   W hen   f irst   v isited,   t he  
web   p age   w ill   s how   t he   f irst   2 0   e ntries   f rom   t he   b eginning   o f   t he   A larm   t able.   T he   f irst   d isplayed   w ill  
be   t he   o ne   w ith   t he   l owest   I D   f ound   i n   t he   A larm   t able.  
The   " Start   f rom   C ontrol   I ndex"   a llows   t he   u ser   t o   s elect   t he   s tarting   p oint   i n   t he   A larm   t able.  
Clicking   t he   b utton   w ill   u pdate   t he   d isplayed   t able   s tarting   f rom   t hat   o r   t he   n ext   c losest   A larm   t able  
match.  
The   s witch   w ill   u se   t he   l ast   e ntry   o f   t he   c urrently   d isplayed   e ntry   a s   a   b asis   f or   t he   n ext   l ookup.   W hen  
the   e nd   i s   r eached,   t he   t ext   " No   m ore   e ntries"   i s   s hown   i n   t he   d isplayed   t able.   U se   t he   b utton   t o   s tart  
over.  
 
Web   I nterface    
To   c onfigure   a   R MON   A larm   O verview   i n   t he   w eb   i nterface:  
1. Specify   P ort   t hat   y ou   w ant   t o   c heck.  
2. Click   S ecurity,   S witch,   R MON,   t hen   A larm.  
3. Check   " Auto-­‐refresh".  
4. Click   "   R efresh"   t o   r efresh   t he   p ort   d etailed   s tatistics.  
 
Figure   3 -­‐5.4.1.3:     RMON   A larm   O verview  
 
 
Parameter   d escription:  
ID  
Indicates   t he   i ndex   o f   A larm   c ontrol   e ntry.  
Interval  
Indicates   t he   i nterval   i n   s econds   f or   s ampling   a nd   c omparing   t he   r ising   a nd   f alling   t hreshold.  
Variable  
Indicates   t he   p articular   v ariable   t o   b e   s ampled  
Sample   T ype  
The   m ethod   o f   s ampling   t he   s elected   v ariable   a nd   c alculating   t he   v alue   t o   b e   c ompared   a gainst   t he  
thresholds.
 
Value  
The   v alue   o f   t he   s tatistic   d uring   t he   l ast   s ampling   p eriod.  
Startup   A larm  
The   a larm   t hat   m ay   b e   s ent   w hen   t his   e ntry   i s   f irst   s et   t o   v alid.  