Auto-­‐refresh:   Check  this  box  to  refresh  the  page  automatically.  Automatic  refresh  occurs  every  3  
seconds.  
Refresh:   C lick   t o   r efresh   t he   p age.  
3-­‐11.3   P oE  
This  page  allows  the  user  to  inspect  the  current  status  for  all  PoE  ports.  This  section  shows  all  port's  
Power   O ver   E thernet   S tatus.  
 
Web   I nterface  
To   s how   L LDP   E EE   n eighbors:  
1.
Click   M onitor,   L LDP,   P oE.  
2.
Display   P ower   O ver   E thernet   S tatus   I nformation.  
3.
Click   A uto-­‐refresh   t o   a uto-­‐update   t he   w eb   s creen.  
 
Figure   3 -­‐11.3:     The   L LDP   N eighbors   E EE   i nformation  
 
 
 
 
Parameter   d escription:  
Local   P ort:  
The   p ort   f or   t his   s witch   o n   w hich   t he   L LDP   f rame   w as   r eceived.    
Power   T ype:  
The  Power  Type  represents  whether  the  device  is  a  Power  Sourcing  Entity  (PSE)  or  Power  Device  
(PD).    
If   t he   P ower   T ype   i s   u nknown   i t   i s   r epresented   a s   " Reserved".    
Power   S ource:  
The   P ower   S ource   r epresents   t he   p ower   s ource   u sed   b y   a   P SE   o r   P D   d evice.  
If   the   device   is   a   PSE   device,   it   can   either   run   on   its   Primary   Power   Source   or   its   Backup   Power  
Source.   If   it   is   unknown   whether   the   PSE   device   is   using   its   Primary   Power   Source   or   its   Backup  
Power   S ource,   i t   i s   i ndicated   a s   " Unknown"    
If   the   device   is   a   PD   device,   it   can   either   run   on   its   local   power   supply   or   it   can   use   the   PSE   as  
power   s ource.   I t   c an   a lso   u se   b oth   i ts   l ocal   p ower   s upply   a nd   t he   P SE.  
If   i t   i s   u nknown   w hat   p ower   s upply   t he   P D   d evice   i s   u sing,   i t   i s   i ndicated   a s   " Unknown."  
Power   P riority:  
Power   Power   Priority   represents   the   priority   of   the   PD   device,   or   the   power   priority   associated  
with   t he   P SE   t ype   d evice's   p ort   t hat   i s   s ourcing   t he   p ower.   T here   a re   t hree   l evels   o f   p ower   p riority.  
The   t hree   l evels   a re:   C ritical,   H igh,   a nd   L ow.    
If   t he   p ower   p riority   i s   u nknown   i t   i s   i ndicated   a s   " Unknown."  
Maximum   P ower:  
The   M aximum   P ower   V alue   c ontains   a   n umerical   v alue   t hat   i ndicates   t he   m aximum   p ower   i n   w atts  
required   by   a   PD   device   from   a   PSE   device,   or   the   minimum   power   a   PSE   device   is   capable   of  