Black Box LPB2910A User Manual page 114

Lpb2900 series gigabit managed poe+ switches
Hide thumbs Also See for LPB2910A:
Table of Contents

Advertisement

The   n umber   o f   B PDUs   a   b ridge   p ort   c an   s end   p er   s econd.   W hen   e xceeded,   t ransmission   o f   t he   n ext  
BPDU   w ill   b e   d elayed.   V alid   v alues   a re   i n   t he   r ange   1   t o   1 0   B PDUs   p er   s econd.    
 
Advanced   S ettings    
Edge   P ort   B PDU   F iltering:  
Control   w hether   a   p ort   e xplicitly   c onfigured   a s   E dge   w ill   t ransmit   a nd   r eceive   B PDUs.    
Edge   P ort   B PDU   G uard:  
Control  whether  a  port  explicitly  configured  as  Edge  will  disable  itself  upon  reception  of  a  BPDU.  
The   p ort   w ill   e nter   t he   e rror-­‐disabled   s tate,   a nd   w ill   b e   r emoved   f rom   t he   a ctive   t opology.    
Port   E rror   R ecovery:  
Control   whether   a   port   in   the   error-­‐disabled   state   automatically   will   be   enabled   after   a   certain  
time.   I f   r ecovery   i s   n ot   e nabled,   p orts   h ave   t o   b e   d isabled   a nd   r e-­‐enabled   f or   n ormal   S TP   o peration.  
The   c ondition   i s   a lso   c leared   b y   a   s ystem   r eboot.    
Port   E rror   R ecovery   T imeout:  
The   t ime   t o   p ass   b efore   a   p ort   i n   t he   e rror-­‐disabled   s tate   c an   b e   e nabled.   V alid   v alues   a re   b etween  
30   a nd   8 6400   s econds   ( 24   h ours).    
Buttons  
Apply   –   C lick   t o   s ave   c hanges.  
Reset-­‐   C lick   t o   u ndo   a ny   c hanges   m ade   l ocally   a nd   r evert   t o   p reviously   s aved   v alues.  
 
102
Publication date: Sept, 2015
Revision A1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpb2926aLpb2952a

Table of Contents