Stratasys J750 User Guide
After examining the UV calibration results:
1.  Click Next.
2.  Remove the UV sensor and close the printer cover. After confirming the 
3.  In the final wizard screen, click Done.
Calibrating the
Load cells are sensors that measure the weight of the material cartridges and 
Load Cells
the waste container in the printer. It is important that you periodically check 
that the weight measurements are accurate to prevent unnecessary waste of 
printing materials. It is recommended that you calibrate the load cells once a 
month.
To calibrate load cells:
1.  Start the Load Cell Calibration wizard from the Options menu.
2.  In the following screen, select one or more load cells that you want to 
3.  Remove each selected cartridge from the materials cart, and click Next.
4.  In the next wizard screen, observe the numbers and wait until the weight 
DOC-08040 Rev. E
items listed in the wizard screen, click Next.
If the results are not acceptable for quality printing, this is indicated in the 
final wizard screen.
Figure 4-108 Final UV Calibration Wizard screen
calibrate. 
Figure 4-109 Load cell selection
level is relatively stable—two units above or below the average level shown.
4 Operating and Maintaining the Stratasys J750 3D Printer
4-71