8.  When the tubes on both sides of the pump are disconnected, rotate the 
9.  Install a new pump cassette.
10. Connect the waste tubes to the new pump cassette.
11. If necessary, replace the pump cassette on the other waste pump.
12. Open the Maintenance Counters screen, scroll down to the General
13. Connect the ground wire to the printer panel and attach the panel to the 
DOC-08040 Rev. E
pump "cassette" assembly counter-clockwise and remove it.
Figure 4-123 Rotating the pump cassette
The new cassette contains a new pumping tube.
Pumps section, and click Reset for the relevant counter(s) (see the figure  
on page 4-28).
printer.