5. Disconnect the UV-lamp power connector and the UV heat fuse
Note: Do not disconnect the power connection to the cooling fans.
6. Loosen the screw securing the UV lamp cover (A), and pull the cover up
7. Pull the UV lamp reflector out of the UV housing.
DOC-08040 Rev. E
connector.
Figure 4-137 Disconnecting the UV lamp
(B), then out (C).
Figure 4-138 Removing the UV lamp cover
Figure 4-139 Removing the UV lamp reflector