6. Connect the INLET side of the new filter to the disconnected (left) tube.
Important:
To connect the filter, hold the fitting at the end of the tube in place and turn the
filter. Otherwise, the tube will be twisted and material might leak.
7. Disconnect the remaining tube from the old filter.
8. Discard the old filter.
Caution:
The filter contains uncured printing material. Discard the filter in accordance
with applicable environmental regulations.
9. Connect the free tube to the right side of the new filter.
Important:
Before connecting the tube to the filter, turn the filter about 90°. When
connecting them, hold the fitting at the end of the tube in place and turn the
filter back to its original position. Otherwise, the tube will be twisted after you
connect it, and material might leak.
10. Wipe the filters, tubes and surrounding area to remove material leaks and
11. Replace the back of the materials cabinet.
12. In the Maintenance Counters screen, click Reset and then Close (see
DOC-08040 Rev. E
Figure 4-128 INLET side of the filter connected to the left tube
spills.
Figure 4-124 on page 4-80).