Uv Lamps 2 - Stratasys J750 User Manual

3d printing system
Hide thumbs Also See for J750:
Table of Contents

Advertisement

Stratasys J750 User Guide
UV
The UV lamps power up and stabilize. (This takes several minutes.) Then, the 
Measurement
print block passes over the sensor and the wizard compares the measured 
radiation to the recommended level for each UV lamp and printing mode. 
During this process, which takes 20–40 minutes, you need to monitor the 
progress as displayed in the wizard screen.
Figure 4-105 UV measurement progress
When using a stand-alone radiation meter, reset the meter and enter the 
reading (measurement) when you are prompted to do so.
Figure 4-106 UV Measurement dialog box
If the UV level measured is not acceptable, the wizard calibrates the UV lamp 
by adjusting the current supplied to it, and then tests it again.
When all UV tests have finished, the results are displayed, showing the 
condition of the lamps after calibration (see Figure 4-107 below).
Figure 4-107 Results and condition of UV lamps after calibration