Setting the Temperature System

Web Agent
Procedure
Document No. 10-300077, Issue 2
You can set the upper and lower temperature warning systems for the switch
backplane and slot 1. These warning systems cause the following to happen
if the temperatures you set are reached:
Shutdown Temperature—The switch shuts down if this
temperature is reached.
Upper Warning Temperature—The switch generates an alarm if
this temperature is reached. If the Shutdown Temperature is
reached, once the temperature drops below the Upper Warning
Temperature, the switch restarts.
Lower Warning Temperature—The switch generates an alarm if
this temperature is reached. Once the temperature rises above this
temperature, the alarm is cleared.
Low Limit Temperature—The switch generates an alarm if this
temperature is reached.
See
Figure 3-7
for the default temperature system settings. You can set the
temperature system using either the Web Agent or the CLI.
To configure the temperature warning systems:
1. In the navigation pane, expand the System > Configuration folders, and
then click Temperature System. The Temperature System Web page is
displayed in the content pane. See
Figure 3-7. Temperature System Web Page for P580