Avaya 580 User Manual page 108

Multiservice switches software version 6.1
Table of Contents

Advertisement

Chapter 3
CLI Command
3-14
2. In the Slot 1 Sensor and Backplane Sensor fields, enter the desired
temperature warnings.
* Note: The P882 does not display the current temperature of the
backplane. In the Current Temperature field, the switch
displays -- .
* Note: If a redundant Supervisor module is installed, the Slot 2 Sensor
column displays.
* Note: You cannot change settings for the backplane temperature
sensors on the P882. If you attempt to change the settings, the
switch displays the following error message:
Set Limits for Backplane Sensor failed -
failure writing to sensor
3. In the CPU Sensor fields, enter the desired temperature warnings.
4. Click APPLY to save your changes, or DEFAULTS to reset the fields to
their default settings.
5. If you change the temperature ranges for the active supervisor, you must
synchronize the active and standby supervisors to copy the temperature
settings to the standby supervisor.
To check the temperature status, use the show temperature CLI command.
To set the temperature thresholds, use the following CLI commands:
(configure)# set temperature {supervisor-slot | backplane-
sensor | cpu-sensor | probe} shutdown <temperature>
(configure)# set temperature {supervisor-slot | backplane-
sensor | cpu-sensor | probe} warning {upper | lower | low-limit}
<temperature>