19. MR-D01 EXTENSION I/O UNIT
19.4 Installation direction and clearances
CAUTION
(1) Installation clearances of the servo amplifier
(a) Installation of one servo amplifier
Cabinet
10 mm
or more
(Note 2)
Note 1. For the 11 kW to 22 kW servo amplifiers, the clearance between the bottom and the ground will be 120 mm or more.
2. To install the MR-J4-500A-RJ, leave a clearance of 25 mm or more between the left side and the wall.
The equipment must be installed in the specified direction. Otherwise, it may
cause malfunction.
Leave specified clearances between the servo amplifier and cabinet walls or other
equipment. Otherwise, it may cause malfunction.
40 mm
or more
Servo
amplifier
10 mm
or more
40 mm
or more
(Note 1)
Cabinet
Wiring allowance
80 mm or more
19 - 11
Top
Bottom