Other Commands - Mitsubishi Electric MR-J4-10A(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 general-purpose interface mr-j4 series servo amplifier
Hide thumbs Also See for MR-J4-10A(-RJ):
Table of Contents

Advertisement

14. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL)

14.5.12 Other commands

(1) Servo motor-side pulse unit absolute position
The following shows how to read the absolute position in the servo motor-side pulse unit. Note that
overflow will occur in the position of 8192 or more revolutions from the home position.
(a) Transmission
Transmit command [0] [2] and data No. [9] [0].
(b) Return
The slave station returns the requested servo motor-side pulses.
For example, data "000186A0" is 100000 pulses in the motor-side pulse unit.
(2) Command unit absolute position
The following shows how to read the absolute position in the command unit.
(a) Transmission
Transmit command [0] [2] and data No. [9] [1].
(b) Return
The slave station returns the requested command pulses.
For example, data "000186A0" is 100000 pulses in the command unit.
(3) Software version
The following shows how to read the software version of the servo amplifier.
(a) Transmission
Transmit command [0] [2] and data No. [7] [0].
(b) Return
The slave station returns the requested software version.
Command
Data No.
[0] [2]
[9] [0]
Absolute position is sent back in hexadecimal in the servo motor-side pulse unit
(Data must be converted into decimal.)
Command
Data No.
[0] [2]
[9] [1]
Absolute position is sent back in hexadecimal in the command unit.
(Data must be converted into decimal.)
Command
Data No.
[0] [2]
[7] [0]
Software version (15 digits)
Space
14 - 39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents