Mitsubishi Electric MR-J4-10A(-RJ) Instruction Manual page 748

General-purpose ac servo melservo-j4 general-purpose interface mr-j4 series servo amplifier
Hide thumbs Also See for MR-J4-10A(-RJ):
Table of Contents

Advertisement

18. MR-J4-03A6(-RJ) SERVO AMPLIFIER
(b) Parameters of 4 to 6 decimal digits
The following example gives the operation procedure to change [Pr. PB03 Positioning command
acceleration/deceleration time constants (position smoothing)] to "65535".
Press "MODE" to switch to the gain/filter setting parameter screen.
Press "UP" or "DOWN" to select [Pr. PB03].
The display can be switched between upper and lower 3-digit by pressing the "MODE" button.
Switching the display between upper and lower 3-digit is also possible by pressing the "MODE"
button while the display is blinking.
The changed value will be canceled when "MODE" is pressed for 2 s or more while blinking.
To shift to the next parameter number, press the "UP" or "DOWN" button.
To change the screen to the other, press "UP" or "DOWN" to change the screen to other parameter
number display screen and press "MODE".
Press the "SET" button once.
Press the "MODE" button once.
Upper 3 digit
Press the "SET" button once.
The display blinks
......
(Note 1)
Change the setting with the
"UP" or "DOWN" button.
Press the "SET" button once.
Enter the setting.
......
(Note 2)
Press the "MODE" button once.
Note 1. Pressing the "SET" button in either upper or lower 3-digit display makes the
display blink.
2. Pressing the "SET" button in either upper or lower 3-digit display fix the setting.
18 - 65
Lower 3 digits
......
...

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents