(3) Connector insertion
Insert the connector all the way straight until you hear or feel clicking. When removing the connector,
depress the lock part completely before pulling out. If the connector is pulled out without depressing the
lock part completely, the housing, contact and/or wires may be damaged.
(4) Compatible wire
Compatible wire size is listed below.
(5) Others
(a) Fix a cable tie keeping a distance of "A" × 1.5 or longer from the end of the connector.
(b) Be sure that wires are not pulled excessively when the connector is inserted.
App. 5.8.4 Wiring FG
Wire size
mm
2
0.22
0.34
0.50
A × 1.5 or more
Wire range
Single wire: φ 0.4 mm to 1.2 mm (AWG 26 to AWG 16)
Stranded wire: 0.2 mm
wire φ 0.18 mm or more
Bottom face
Lead wire
App. - 33
AWG
24
22
20
2
to 1.25 mm
2
(AWG 24 to AWG 16),